All servicesFire protection system design↗Fire detection and alarm↗Fire suppression systems↗System maintenance↗Other systems↗Passive fire protection↗About↗Insights↗Contacts
About the system

Fire suppression systems in Kyiv and Ukraine

A fixed fire suppression system releases an extinguishing agent to control or extinguish a fire. We select the system type individually according to occupancy, protected materials, equipment and project requirements.

KABO GROUP reviews the available information, prepares an agreed technical scope and completes the work with the defined documentation.

Solutions

What is included in fire suppression systems

Practical guide

System details and solution selection

How the solution is selected

We assess the building use, protected area, fire risks, existing engineering services and the required performance before agreeing the technical solution.

What affects scope and cost

The estimate reflects system size, equipment or materials, access conditions, interfaces, commissioning and the completion documents agreed for the project.

From survey to handover

KABO GROUP can survey, design, supply, install, test and hand over the system, followed by planned maintenance where required.

Selecting an automatic extinguishing system

Water, foam, gas, powder or aerosol is selected for fire class, fuel load, occupancy, acceptable collateral damage, enclosure integrity, temperature and recovery needs.

Warehouses require analysis of height, storage arrangement, racks and commodity category. Data rooms and archives also require evacuation, power isolation, enclosure integrity and safe agent removal.

Calculations and extinguishing-agent supply

Water systems require design density, operating area, flow, pressure, pipe sizes, pumps and water storage. Gaseous systems require concentration, agent quantity, discharge network, discharge time, pressure relief and leakage assessment.

Hydraulic or specialist calculations connect the risk to the actual network. Later changes to routes, sprinklers, pumps, tanks or room layout require verification rather than assumption.

Release logic, interlocks and acceptance testing

Automatic release is coordinated with fire detection, warning, ventilation, process equipment and access control. Confirmation, delay, manual release, inhibit and abort functions are defined by the design.

Before handover, networks, valves, pumps or cylinders, status signals, standby power and the full cause-and-effect are tested and recorded.

Regulatory basis

Regulations and standards considered

This list explains the regulatory basis but is not a substitute for a project or a complete schedule for every building. Document status, amendments and building-specific requirements are verified when the project starts.

VIDEO / HOW IT WORKS

See how fire suppression works

These Ukrainian-language videos explain automatic fire suppression and the differences between the main system types.

All channel videos ↗
How it works

Автоматичні установки пожежогасіння: види, принцип роботи та переваги

An overview of automatic suppression systems, activation, main types and applications.

Open on YouTube ↗
Expert guide

Автоматичне пожежогасіння: вода, порошок чи газ

A comparison of water, powder and gas systems and the risks each system is designed to address.

Open on YouTube ↗

Videos are published by the Ukrainian-language channel Fire Safety of Ukraine. The project defines the system components, operating logic and equipment for each site.

Outcome

One accountable delivery cycle

Risk-based technical solution✓Design and equipment schedule✓Installation✓Commissioning and agreed documentation✓
Process

Work stages

Building information

We receive plans, occupancy information, equipment characteristics and a description of the protected risks.

Survey and risk review

We verify protected zones, actual conditions and restrictions on extinguishing agents.

System selection

We compare water, gas, powder, aerosol or other suitable configurations.

Design and estimate

We prepare the technical solution, equipment schedule and an agreed cost proposal.

Engineering practice

The solution is visible in the details

The focus is on real details, materials, installation and verification that determine the result.

Engineering practice: Fire suppression systems
Practical quality and compliance control
Technical system details: Fire suppression systems
Details, materials and delivery conditions
FAQ

Common questions

Which extinguishing system should be selected?+

The choice is made only after assessing people, protected materials, equipment, occupancy and applicable requirements.

How does the work begin?+

We start with the available information, a site survey and an agreed technical brief.

What determines the cost?+

Cost depends on floor area, building configuration, system scope, access conditions and the required completion documents.

Short request

Request a preliminary estimate

By submitting, you agree to data processing for the purpose of answering your request. Privacy policy.